Basement – How should I insulate the partially finished, currently uninsulated basement

basementenergy efficiencyenergy-auditgarage-doorinsulation

I am in Alabama, climate zone 3. Half of my basement is finished, well at least it has a dropped ceiling, wood panel walls, an air supply and return, but no insulation. There is an uninsulated partition wall with some gaps near the AC ductwork dividing the basement roughly in half. On the other side is an incidentally heated space containing a water heater, furnace, and dryer. It also has a single car roll up garage door. All the flooring above is hardwood or tile.

The basement is roughly 20'*60' using cinderblock construction. One of the long walls is completely below grade while the other is completely above grade. All the below grade walls have some sort of vapor barrier installed.

How should I go about insulating this space? I'm thinking foam board would be the best way to go. Should I insulate the section of wall that's below grade? And what should I do about the vapor barrier? Also, is there any good way to insulate the garage door? And finally should I add insulation to the ceiling of the incidentally heated unfinished side of the basement? The side of the house above that part of the basement gets noticably colder.

Pics of everything:
https://imgur.com/gallery/6Mc8Oxa

Best Answer

I have a similar setup as you. Same Climate Zone (Georgia, USA) and similar type of basement and walls. Since the vapor barrier could cause water condensation in the wall if you go with drywall, you'll want to remove it. I am going to seal my wall with a heavy masonry sealer like DryLock first. Then use foam board because it would be mold resistant. If you use furring strips I would probably paint them too to inhibit mold growth. I would insulate all the exterior walls.

You didn't say if you were going to refinish the area after removing the paneling, but if you do, consider waterproof/water-resistant materials like mold-resistant/mold proof drywall and PVC trim. Basements in general are notorious for water infiltration and mold damage, so this would help mitigate it. Also, if this area is to be made into a livable, usable space where people could spend some time in, consider getting a radon test done as well.

You didn't state what material your garage door is made of. If it is wood, I would probably just replace it with an insulated metal door. If you have a metal door that is un-insulated, you can cut foam insulation inserts and fit them between the panels. For looks you could also screw new sheet metal rectangles over and paint it if you don't like the foam to be visible.

Also, I'm not sure about your ceiling in the unfinished side of the basement. You mentioned a drop ceiling. If there is drop ceiling in that area, then use insulated drop ceiling tiles. You can make your own out of luan plywood and some thin foam insulation if you want. if not, then you should be able to use batt insulation to insulate the ceiling joists.