I want to hang a baby bed in our bedroom (less than 20kg /44lbs).
I drilled a hole into the concrete ceiling.. which i was expecting to be quite thick, but its actually only about 4cm (1 9/16") depth!
I'm guessing it's made of stuff like in the pics below (as when i view this slab from the balcony it's very thick)
Originally i was thinking of using expansion bolts… but from reading data sheets it seems like i need a hole deeper than 4cm (1 9/16")
So thinking instead of using toggle bolts.
The questions are:
- Is 4cm (1 9/16" concrete) ok to be drilling and hanging 20kgs (45lbs)
? - Any issues with using Toggle bolts to handle that weight?
- i read the data sheet from PowerFasteners (see snapshot below) and it seems to be totally fine Any issues with drilling two holes close to each other as a backup?
PowerFasteners Toggle Bolt Data sheet:
Allowable Load tension values look fine…
thanks in advance!
Best Answer
I would not put my faith in a regular toggle bolt. The small bend pin that acts as a hinge for the wing to pivot on and are critical for its integrity seem weak at best. I would rely on it for shear strength rather than tension.
Here is what I would use instead...