Electrical – Joining two 10mm twin and earth cables

electricalukwiring

I've had an electrician install some new wiring for me for our new electric car charger. It is 10mm twin and earth. He's had to join two of these together, he hasn't fully finished yet, but I'm wondering if the join he has made is sufficient. I've attached a photo of his work.

The join is inside a void under our stairs behind some plasterboard. It will be taking a current of 16A for approximately 9 hours at a time. In the future our new car will be taking 30A. I'm a little concerned that this tape job isn't right. Any advice would be great. pic

Edit: Here is picture without the tape
enter image description here

Best Answer

I've never seen a qualified electrician leave twisted and taped up wires in 30 years on the job. And that is because it is a ridiculous way to form a connection. The tape will degrade over time and turn into a sticky mess. Put the connection into a proper junction box rated for the job, they cost pennies.

p.s. I could nearly live with it, if the wires were soldered and then the whole thing put into a box, but even then the tape won't last forever.