I have moved to a property with 5amp round sockets around the room. I want to remove the standard 3 pin plugs from my table lamps and re-wire them with the 5amp round pin plugs I have bought. This means they will be on a mains dimmer circuit, so I can choose to have the spotlights on, or the lamps come on with one switch. The problem is, 2 of the table lamps have 3amp fuses in. Can I safely attach them to a 5amp round pin plug and put them in the sockets without blowing anything up?
Electrical – modify 3 ampere table lamps to work on 5 ampere round pin plugs
electricallighting
Related Topic
- Electrical – How to change an old 3 round pin socket to a square pin socket in a newer house
- Electrical – Protecting electronics from electrical surges – plugs with fuses
- Electrical – Is it safe to replace a lamp’s UK 5 amp round 3 pin plug with a 13 amp rectangular 3 pin plug
- Lighting – ELV to 5amp circuit
- Electrical – change the plugs on low-voltage lights to allow connection to dimmable outlets
- Electrical – change normal plug to a 15amp round pin plug
- Electrical – rewire an audio amplifier with a round pin plug to fit sockets in living room made for lamps
- Electrical – Wiring and Fusing a 5A Round Pin Socket
Best Answer
3A lamp on 5A outlet
You should be OK to use a 3A appliance on a 5A circuit. The circuit is capable of supplying up to 5A but it is the individual appliance (lamp in this case) that determines how much current is drawn.
Round-pin plugs vs rectangular-pin plugs
Modern usage
I'm surprised a new home would have BS 546 round-pin plugs instead of the more usual BS 1363 rectangular-pin plugs.
Wikipedia says
Until now, I thought the only place where round-pin plugs were used was in theatrical stages, where I think they are used to prevent people plugging inappropriate devices into theatrical lighting circuits.
Safety
If the BS 546 plugs don't have built-in fuses, they don't provide any protection to the line-cord between the plug and the lamp.
BS 1363 plugs have additional safety features which may not be present in BS 546 plugs
For example a small child can poke their hands (or part of a metal toy) behind a loose BS 546 plug and be in contact with 230 V.