Hot Springs Spa will not heat

hot-tub

My 2005 Hot Springs Envoy spa will not heat.

  • Heater light is on.
  • On the circuit board:
    • Lim Ok has green light,
    • HTR On has Red light.
  • Circulation pump is running.
  • Heater Relay Board and wires going to heater:
    • Black wire reads 17V,
    • White 121V,
    • Red 121V,
    • combo or Red & White 214V.

I'm not sure why the Black would read 17V. Is that normal? Do you think I need a new relay board or heater?

Heater placard says 240V 4KW SSE-00-0H-0f was red tape

Best Answer

It looks like a fuse or some other safety has opened. Black to red on the heater is usually 240v with an intact heater and an open fuse on the black you will still read voltage as some is coming through the heater.