How to add a fireplace to an existing non-fireplace chimney

chimneyfireplace

Our 83 year old house has a brick chimney covered up with drywall. We have no idea where the original flue was, but it must have vented a wood stove because there is no structure for a fireplace.

We want to install a zero-clearance wood-burning fireplace. The best place (to our mind) would be in the living room, which means that it would squeeze into a corner of the living room, with a doorway on either side of the hearth. I know we will have to install an insulated chimney liner esp. since there is combustible material against the chimney. Our rough plan is to place a lightweight floor protector, rather than a stone hearth, so the floor can bear the weight. Because we cannot stick the stove "into" the wall because there is no fireplace opening, the new fireplace vent would have to bend into the chimney at some point, and we would have to cut a hole into the brick chimney for the flu. Also, the fireplace will "stick out" into the room, so we will have to make a mantel/hearth around it that will basically eat up 1/6th of the living room.

I'm a novice at this, and am sure I've missed some details. Any advice or suggestions?

Is it possible to cut through the brick?

Is bending the vent pipe a good idea?

Will the chimney be a fire hazard even with insulated liner?

Our other option is to wait, and build a new chimney/fireplace into a one-room extension we plan to add to our two-story house. But everything I've read says never to do that… and that chimneys on exterior walls cause poor air flow.

Best Answer

I realize this post is "old" however I wanted to post the answers as the information is always relevant to future question askers! :)

I sold venting pipe professionally for 4 years, and have experience designing a variety of systems.

Just a few notes: 1. Always check your clearances to combustible materials. Zero-clearance fireplaces are only zero clearance to certain materials, like masonry, etc. Make sure you take care when addressing this.

  1. Different stoves have different pipe diameters. If you're still debating which model to get, you could save yourself some money by going with 6" diameter versus 8", as the larger it is the more expensive.

  2. Old masonry chimneys are dangerous and should be inspected, even if using a liner.

Onto the parts! Since you are going to be dealing with a freestanding stove as well as a chimney liner, you're likely going to need an adapter as you enter the masonry.

When you come off of your stove with the flue pipe, you would want double-walled black stovepipe. This has a twist-lock connection that will go on your stoves outlet, either top or rear vented. It is more expensive than single-walled pipe, has less clearance requirement of 8 inches versus (18-inch clearance of single-wall) but has longer life, and isn't burning hot to the touch.

Your question about bending the pipe: Definitely do not ever physically bend a pipe to create a curve, etc. Rather, use an angled piece, then a straight, and then another angled piece to complete the connection. This stove-pipe comes with "elbows" at various angles. 45/90 degree are the most common, so you should have no issue angling the pipe to penetrate the masonry at 90 degrees.

The easiest way to complete your system would be to adapt the standard stove-pipe to a masonry liner. For a normal chimney-pipe to masonry-liner system, you will need a few pieces that aren't "standard" on most installations.

Masonry Thimble: This item installs into the 6-8" diameter hole you drill in your masonry chimney. It allows a length of straight pipe to pass through your masonry wall, into the chimney, and connect to the flexible stainless chimney liner. Stove-pipe to Liner Adapter: This piece physically adapts the rigid interior stove pipe to flexible liner.

You asked if the chimney can be a fire-hazard even with a liner; The short answer is yes. The reason being that if there is not enough clearance from the edge of the chimney interior to the outside edge of the chimney liner pipe; heat can be transferred to the brick, which can then catch wood aflame. If you have proper clearance, no fires should occur from the liner/masonry portion.

The only other fire-hazard that should exist is the chimney-cap itself. Make sure that the termination (last pieces) are done correctly. Is there a masonry chimney penetrating above the roofline a good bit? If so, you have it easy and can purchase a Turbo cap with a "spark arrestor" screen.. The cap spins as the heat exhausts out, cooling it, and the screen catches any flaming embers or sparks that might still exist from the burning wood.

Regarding your "Chimneys on exterior cause poor air flow" Statement: From my experience that is mostly false. Only in situations where there are EXTREME weather conditions does this ever occur. The reason this is never a problem with correct installations is that the Class A pipe required for exterior installations is either double wall or triple wall insulated. There are numerous layers of insulation that keep the flue gasses piping hot (ha) until they exit the chimney cap. Please keep in mind when designing a chimney system you want to achieve this: Most air flow. Least bends. Shortest run.

Numerous elbows/Angles cause the exhaust to cool. A rule of thumb is no more than 3 90 degree turns total from stove to cap.

I hope this helps!