Whether dope is required at all, is dependent on the type of threads. The type of thread is determined by the tap or die used to create the threads, and should be labeled on the pipe or fitting.
Thread Standards
National Pipe Thread (NPT)
This type of thread when mated, may contain slight gaps between the major and minor diameter of the threads. Because of this, a thread seal agent may be required. However, this type of thread is tapered at a rate of 1/16 (3/4"/foot), which often allows a seal to be made without a sealing agent.
May be listed as MNPT or FNPT, for male and female threads respectively.
National Pipe Thread Fuel (NPTF)
NPTF threads are designed so that when the threads are mated, they actually deform to create a mechanical seal. Since the seal is created by the threads themselves, a thread seal agent is not required (though may be used as a lubricant).
May be listed as MNPTF or FNPTF, for male and female threads respectively.
National Pipe Straight (NPS)
This type of thread is similar to NPT, except that the thread does not have a taper. A thread seal agent is required, but should be selected differently due to the lack of taper.
May be listed as MNPS or FNPS, for male and female threads respectively.
National Pipe Straight Fuel (NPSF)
NPSF like NPTF creates a mechanical seal due to the deformation of the threads, however, unlike NPTF NPSF threads are not tapered.
May be listed as MNPSF or FNPSF, for male and female threads respectively.
Selecting Dope
Which form of dope you choose is often based on who you learned from, personal preference, what's on hand, what type of pipe you're working with, etc. The following are my personal guidelines.
Water
Plastic, Soft Metals, Unreactive Metals
In this situation I'll reach for PTFE tape, since it's not likely I'll require long term corrosion protection. I'm just looking to lubricate the joint, so I can tighten it to create a leak free joint.
Steel, Reactive Metals
Because I don't want the threads to rust or react negatively, in this situation I'll use paste dope. The paste dope will give me the lube I need to get the pipes properly joined, while at the same time providing corrosion protection. The paste dope will never harden or flake off, so I know the threads will be protected for a long time.
Large Diameter Pipe
If I'm working with water pipe of any material larger than ~1", I'll always use paste dope. I don't really have any particular reason for this, it's just the way I was taught.
Fuel Gas
When working with fuel gas pipes of any kind, I always use a paste dope labeled for this use. This is especially true when working with "black" pipe, since I want some corrosion protection in these joints.
Tapered VS. Straight Threads
Tapered Threads
For pipes and fittings with tapered threads, I'll simply follow the guidelines mentioned above.
Straight Threads
When working with fittings with straight threads, paste dope should always be used. Tape dope is too thick, and can actually prevent a good seal in straight thread joints. Paste dope will spread and be pushed out of the way, and will not prevent the threads from properly engaging.
The only place tape is to be used is on threads, to be exact, tapered threads, the kind that are on pipe nipples, or the male threaded ends of valves for example. These are the kind that get tighter as you twist the parts together. If you look at the threaded end you can see the pipe is smaller at the end than farther down the length. Pipe dope can be used on these threads too. Pipe dope, otherwise can be used on the various types of compression fittings, the type that use a ferrule. When using metal pipe the type of pipe dope is not that critical, but if using plastic, be careful, there is pipe dope NOT for plastic.![enter image description here](https://i.stack.imgur.com/aEMxk.jpg)
In a nut shell, tape is for tapered threads only, dope can be used too. and either must be used or a leak will occur. Dope is to be used only on mating surfaces, flat, smooth or rounded. It is mainly insurance in my opinion, and I use it too, but the mating surfaces should make a tight fit on their own. I have had a many a leak before using dope, now the leaks are non-existent. Then again, maybe I just got better at it finally....
Best Answer
no - pipe dope can pretty much be used everywhere. its not necessary though on anything but a thread to thread seal. most vanities nowadays use flexible supply lines that have compression type fittings at either end with a rubber seal in them. its not necessary on that connection at all.