The correct way to seal/flash coolant lines through T1-11 siding

air-conditioningflashinghvacsiding

Our contractor installed an AC compressor and did a poor job of it.
He ran the AC coolant lines through the middle of the wall and then just squirted some expanding foam into the hole, like so:

(Click images for larger views.)
Bogus flashing 1 Bogus flashing 2

What is the correct way to flash and/or seal this opening?


Around here, the way its usually done on T1-11 sided houses is to pass the lines underneath, in the crawl space and through a vent, like so:

Typical line routing

But I guess that's not an option in this case?

Best Answer

There are all kinds of options, but the cleanest are probably purpose made flashings specifically for AC lines, like these ones:

enter image description hereenter image description here

Note that it is very important to tie a flashing like this into the overall water-resistive barrier to the house, similar to a flanged window.

The "vent" entrance method would only work on a raised foundation structure, the home in your picture appears to be built on a concrete slab.