What could be causing an A/C blower motor to turn off randomly

air-conditioningcentral-airhvac

The Blower motor on my AC unit turns off at random times while the outside unit continues to run which is causing the coil to freeze up. The blower won't come on for 30-45 minutes after the AC has been turned off, but after that it seems to turn back on fine. I have been trying to track the problem down for the last couple months, but it literally only happens every 2 or 3 weeks.

Last night it stopped again and I tried to just turn the fan (from the thermostat) on without luck. I took a look at the blower and it seemed to turn just fine. I put my hand on the back of the fan motor and it wasn't hot to the touch.

About 45 minutes after it turned off the blower came back and it was working normally. What could be causing this problem?

Best Answer

I ended up calling a buddy of mine who is an HVAC tech and he pointed me in the right direction to check the fan wire on the back of the thermostat. I checked the wire and it was just hanging in the terminal. I'm pretty sure that was the cause of the problem. It makes sense because there wasn't anything wrong with the blower motor itself.

The fan wire on the thermostat was in fact the problem. I fixed the connection and it has worked fine for the last 3 years.