Just had this hot water heater installed approximately 2 years ago. I’m not sure what is causing the corrosion. Also, the tenant said the water inside is way too hot and that it started about three weeks ago.
Plumbing – Does anyone know what has caused this corrosion on hot water heater
plumbing
Related Topic
- Plumbing – Why does this toilet valve have corrosion on it
- Plumbing – What could be causing a steady tapping noise in a tankless water heater
- Plumbing – Corrosion around hot water heater connection
- Plumbing – What causes this green residue on pipe going into hot water tank
- Plumbing – Water heater too hot, possibly caused by low water flow
- Plumbing – Why does this pipe feeding a hot water heater dip down like this
- Plumbing – Plumber wants to replace PRV valve into house at same time he is replacing hot water heater
Best Answer
The corrosion is being caused be a poor solder job. The joints are slowly leaking. Next time get a real plumber to do the job and don't call this company back. By the way, the discharge pipe for the T&P valve is to be run in a full pipe size not a reduced pipe or tubing as it looks like yours was installed. That in itself shows that the "butcher" that installed this water heater needs to find a different line of work. If by chance the installing company is a good and reputable company, call them back and show them work done by their employee and maybe they will re-do the installation for free or at a reduced rate.